JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação Periódicos - Resumos por ano de publicação "2022"
-
VARDASCA, I.S.
; REGIS, M.A.
; ZEZELL, D.M.
; FRANCCI, C.
.
O uso de fontes de luz em protocolos clareadores: alteração de cor, temperatura, transmitância e irradiância: estudo in vitro.
Brazilian Oral Research,
v. 36,
suppl 1,
p. 306-306,
2022.
Abstract:
O objetivo do presente estudo foi avaliar as alterações de cor superficial, temperatura, transmitância
e irradiância de diferentes fontes de luz em alguns protocolos de clareamento em consultório com
peróxido de hidrogênio (PH) de baixa concentração. 90 blocos de esmalte/dentina humanos foram
pigmentados e separados em 9 grupos(n=10): SG-SL (sem gel-sem luz), SG-VIO (sem gel, com exposição
ao LED violeta), PH35%-SL (sem luz), PH17,5%-SL, PH6%-SL, PH17,5%-AZUL (com exposição ao
LED azul), PH6%-AZUL, PH%17,5-VIO (exposição ao LED violeta) e PH6%-VIO. A avaliação da
cor foi realizada 7, 14 e 21 dias após o início e 14 dias após o término do protocolo de clareamento
com espectrofotômetro, com os valores L*a*b* de reflectância, através do whiteness index (ΔWID
). A análise da temperatura foi realizada com um termopar, a transmitância das luzes com uma
esfera integradora e a irradiância das luzes com um powermeter. ANOVA com post-hoc Tukey para
as análises de alteração de cor, temperatura e transmitância. O teste de Mann-Whitney foi utilizado
para a irradiância. Como resultado, os grupos PH17,5 apresentaram (ΔWID ) similar ao PH35%,
independente das fontes de luz. Todos os protocolos irradiados com fontes de luz apresentaram
alteração de temperatura maior de 5,5ºC, exceto SG-VIO. A transmitância foi maior no LED azul e no
PH17,5%, e a irradiância foi maior no LED azul.
Conclui-se que o uso de fontes de luz associadas a géis clareadores de menor concentração não
melhoram o resultado estético, porém há um aumento considerável da temperatura, maior no LED
Azul que no violeta.
VARDASCA, I.S.; REGIS, M.A.; ZEZELL, D.M.; FRANCCI, C.
O uso de fontes de luz em protocolos clareadores: alteração de cor, temperatura, transmitância e irradiância: estudo in vitro.
Brazilian Oral Research,
v. 36,
p. 306-306,
2022.
suppl 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/33573. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, FABIO A. da
; BERNARDES, EMERSON S.
.
Uncovering the role of modified citrus pectin in cancer.
Nuclear Medicine and Biology,
v. 108-109,
S1,
p. S176-S177,
2022.
DOI:
10.1016/S0969-8051(22)00371-7
Abstract:
Background: Modified citrus pectin (MCP) is a polysaccharide
consisting of galacturonic acid with anti-cancer activity that can act
synergistically with other treatments to reduce tumor growth, stimulate
programmed cell death and reduce the number of metastases.
In addition, MCP prevents acute and severe renal syndromes caused
by radiation/chemotherapy. All of these effects were reported to be
due to MCP ability to specifically inhibit Galectin-3 protein functions.
Aims: The aim of this work was to evaluate the anticancer effect
of MCP in a Balb/c nude mice xenograft model of ovarian cancer.
Methods: The human ovary cancer cell line, SKOV-3, was subcutaneously
injected in Balb/c nude mice and tumor growth was monitored
daily with a caliper. When tumors reached 250-300 mm3, 20
mg/kl of MCP was administered intravenously (I.V.) in a daily based
for 21 days. Tumor growth and mice weight were monitored daily.
Additionally, MCP was radiolabeled with 99m-technetium (99m-Tc)
with the incubation of MCP (2.5 mg) in saline with SnCl2 (4 mg/
ml), HCl (0.01 M), NaOH (0.01 M) and 99mTc (129,5 MBq) at pH=7
for 30 min. The radiochemical purity was determined by iTLC-SG
with acetone and ethanol/NH3/H2O (1:2:5). 99mTc-MCP (37 MBq)
was administrated I.V. in Balb/C nude mice bearing SKOV-3 tumors
and after 1, 2 and 4 hours, SPECT/CT image was acquired (Albira SI
Buker). Ex-vivo biodistribution studies were performed after the I.V.
injection of 10 MBq of 99mTc-MCP for 1-hour. The % of injected dose per gram (%ID/g) of tissues of interest was calculated. The tumors
were removed, fixed, cut and used for autoradiography studies and
stained with hematoxylin and eosin (H&E) to verify hypoxic regions.
Results: The I.V. administration of MCP was able to significantly
reduce SKOV-3 tumor growth (52% tumor volume reduction) in
comparison with the non-treated group, after 21 of treatment. Our
biodistribution studies showed that 99mTc-MCP was mainly found
in kidneys, bladder and liver of mice (%ID/g = 12.25, 38.57 and 5.71,
respectively), and was able to reach the tumor (%ID/g = 0.765 ±
0.045) 1-hour after I.V. administration. 99mTc-MCP accumulation in
the tumor site was visualized by μSPECT/CT imaging 1 hour after I.V.
administration. The autoradiography and stained (H&E) study demonstrated
a correlation between MCP and regions of tumor necrosis.
Because of MCP high accumulation in kidneys, renal toxicity was also
evaluated. We were able to find that MCP doesn’t induce renal toxicity
when administered in a daily base at a concentration of 20 mg/Kg.
Conclusion: In this work we demonstrated that a daily treatment
of MCP was able to reduce tumor growth of ovarian tumor xenografts
(SKOV-3 cells) without showing renal toxicity. We found too that
MCP can reach the tumor site, binding mainly in regions of necrosis.
However, other studies are needed to unravel the mechanisms of
action that act on the antitumor effect of MCP.
SILVA, FABIO A. da; BERNARDES, EMERSON S.
Uncovering the role of modified citrus pectin in cancer.
Nuclear Medicine and Biology,
v. 108-109,
p. S176-S177,
2022.
S1,
DOI:
10.1016/S0969-8051(22)00371-7.
Disponível em: http://repositorio.ipen.br/handle/123456789/33225. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BIANCOLLI, ANA L.G.
; BARBOSA, ANDREY S.
; KODAMA, YASKO
; REY, JOSE F.Q.; FONSECA, FABIO C.
; SANTIAGO, ELISABETE I.
.
The influence of pre-irradiation and simultaneous grafting methods on the physicochemical properties of polyethylene-based anion-exchange membranes and ionomers.
ECS Meeting Abstracts,
v. MA2022-01,
n. 35,
2022.
DOI:
10.1149/MA2022-01351499mtgabs
Abstract:
Controlling the synthesis parameters during radiation-induced grafting (RIG) is a key feature to design anion-exchange membranes (AEMs) with enhanced properties that lead to high performances and stability. The present study provides a systematic investigation of the effect of RIG methods on physicochemical properties of LDPE-based AEMs with similar degree of grafting (DoG) and ion exchange capacity (IEC). The LDPE films were grafted with 4-vinylbenzyl chloride using two methods: i) pre-irradiation (PIM), using electron-beam (EB), and ii) simultaneous (SM), using gamma-ray (γ), both in air atmosphere and with different absorbed doses. The AEMs grafted by SM were irradiated with 20, 25, and 30 kGy, while the ones grafted by PIM were irradiated with doses of 30, 70, and 100 kGy. Samples grafted by the two different methods have the same molecular structure, but distinct physicochemical properties due to markedly differences in the degree of crosslinking. The studies have shown that grafting step directly influences the internal structure and morphology of AEMs. Multi-technique characterization demonstrated that RIG method determines the mechanical properties, water transport, and the distribution of ionic groups in AEMs. These characteristics have direct impact on fuel cell performance, anion-conductivity, and AEM stability.
Figure 1 shows the polarization curves of anion-exchange membrane fuel cells (AEMFCs) operating at 80 °C with AEMs grafted by PIM and SM. Comparing AEMFCs performances containing AEMs with similar IECs from the two different grafting methods, it is possible to notice that AEMs synthesized by PIM, in general, promote better fuel cell performances than the corresponding ones prepared by SM. The main differences in the polarization curves are evidenced in the ohmic and the mass transport limiting regions. This result suggests that water management is enhanced in AEMs synthesized by PIM compared to the SM-AEMs. A membrane that allows rapid back diffusion of liquid water from the anode to the cathode, should reduce the current losses due to mass transport limitations.
The gel content results confirmed the presence of more crosslinking in membranes synthesized by PIM than in the ones synthesized by the SM. As a consequence of that, enhanced mechanical properties were found for PIM-AEMs, indicating polymer backbone reinforcement due to high degree of crosslinking. Small-angle X-ray scattering measurements have confirmed that the microstructure of PIM and SM AEMs are different and this feature is directly related to ion conduction and water transportation.
Figure 1. AEMFCs performances at 80 °C with LDPE-based AEMs grafted by the pre-irradiation method and by the simultaneous method. H2 anode gas flow=0.8 L min-1, O2 cathode gas flow=0.5 L min-1, both supplied unpressurized with optimal dewpoint temperatures ranging from 77 to 80 °C. AEMs are referred according to the grafting method and absorbed dose. 30 and 70-EB-PIM refer to the samples irradiated with 30 and 70 kGy, respectively, in the EB accelerator and grafted by the pre-irradiation method. 20 and 25-γ-SM refer to AEMs irradiated with 20 and 25 kGy, respectively, by γ-rays and grafted by the simultaneous method.
BIANCOLLI, ANA L.G.; BARBOSA, ANDREY S.; KODAMA, YASKO; REY, JOSE F.Q.; FONSECA, FABIO C.; SANTIAGO, ELISABETE I.
The influence of pre-irradiation and simultaneous grafting methods on the physicochemical properties of polyethylene-based anion-exchange membranes and ionomers.
ECS Meeting Abstracts,
v. MA2022-01,
n. 35,
2022.
DOI:
10.1149/MA2022-01351499mtgabs.
Disponível em: http://repositorio.ipen.br/handle/123456789/33407. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ARAUJO, JOAO V.
; MILAGRE, MARIANA X.
; GABBARDO, ALINE D.
; KLUMPP, RAFAEL E.
; COSTA, ISOLDA
.
The effect of tartaric-sulfuric acid (TSA) anodizing on the corrosion resistance of the AA7475-T761.
ECS Meeting Abstracts,
v. MA2022-02,
2022.
DOI:
10.1149/MA2022-02142475mtgabs
Abstract:
The microstructure of the high strength aluminum alloy, AA7475–T761, in the as-received condition was characterized by optical microscopy, scanning electron microscopy and transmission electron microscopy, and statistical analyses of grain size and micrometer precipitates distribution and density were performed. An anodic aluminum oxide (AAO) film was potentiostatically grown on the alloy in tartaric sulfuric acid (TSA). The anodizing behavior of the alloy and the mechanisms of localized corrosion initiation and propagation in bare (not anodized) and anodized conditions were discussed. The alloy corrosion behavior was investigated in sodium chloride solutions using electrochemical techniques (cyclic potentiodynamic polarization) and the morphology and extent of corrosion propagation was investigated through optical microscopy, optical profilometry and scanning electron microscopy analyses. It was observed that the two alloy surface conditions (bare and anodized) play different roles in the propagation of the localized corrosion process. The bare alloy presented lower localized corrosion potentials and the propagation of the localized corrosion was shallower, but more heavily distributed, than in the anodized condition. However, the alloy in the anodized condition presented lower repassivation potentials due to the deeper pits formed. In addition, the variability of pitting potentials for the anodized condition was high, due to the heterogenous structure of the AAO film formed, and dependent on the time and drying storage conditions previous to electrochemical characterizations. The electrochemical results were correlated with the microstructural characteristics of the oxide surface film of the alloy in both conditions, bare (not anodized) and anodized.
ARAUJO, JOAO V.; MILAGRE, MARIANA X.; GABBARDO, ALINE D.; KLUMPP, RAFAEL E.; COSTA, ISOLDA.
The effect of tartaric-sulfuric acid (TSA) anodizing on the corrosion resistance of the AA7475-T761.
ECS Meeting Abstracts,
v. MA2022-02,
2022.
DOI:
10.1149/MA2022-02142475mtgabs.
Disponível em: http://repositorio.ipen.br/handle/123456789/33867. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FONTES-OLIVEIRA, Y.R.
; CARAMEL-JUVINO, A.
; AVELINO, S.G.
; ZEZELL, D.M.
.
Protocolos de associação de flúor e laser de alta potência (Nd:YAG) na prevenção da cárie: revisão de literatura.
Brazilian Oral Research,
v. 36,
suppl 1,
p. 346-346,
2022.
Abstract:
Avaliar os protocolos publicados para prevenção da cárie utilizando associação de flúor e laser Nd:YAG.
Foram utilizadas seis bases de dados: Web-of-Science, PubMed, ResearchGate, Google Acadêmico,
LILACS e Scielo. Dos 115 artigos inicialmente coletados, foram excluídas as duplicatas, artigos com
dentes bovinos, artigos sem flúor gel ou que abordavam erosão. Foram selecionados 12 artigos. Sobre
os efeitos do tratamento, os artigos relataram que a irradiação laser promove fusão e re-solidificação
da superfície, tornando-a mais ácido-resistente. Quando associado a fluoretos, este laser aumenta a
superfície de contato para a ação do flúor, potencializando os seus efeitos. Analisando os parâmetros
utilizados na irradiação, a maior parte (50%) usou 0,6W de potência e 84,9 J/cm² de fluência, seguido
pelos valores menores 0,5W e 70,7 J/cm² (16,6%). Estes parâmetros foram considerados seguros em
estudos que avaliam a possibilidade de dano térmico à polpa. Dentre os estudos que compararam os
efeitos da aplicação de flúor prévia ou posteriormente à irradiação laser, apenas 8,3% relataram que o
tratamento sinérgico com laser de Nd:YAG e flúor não foi mais eficaz do que o flúor isolado. Já 33,3%
apresentaram melhores efeitos com a aplicação de flúor depois do laser e 8,3% obtiveram melhores
resultados com aplicação antes do laser. 8,3% concluíram que o resultado independe da ordem.
O protocolo de 0,6W de potência e 84,9 J/cm² de fluência, com aplicação de flúor posterior a irradiação
laser, apresentou resultados satisfatórios na prevenção da cárie para a maioria dos estudos.
FONTES-OLIVEIRA, Y.R.; CARAMEL-JUVINO, A.; AVELINO, S.G.; ZEZELL, D.M.
Protocolos de associação de flúor e laser de alta potência (Nd:YAG) na prevenção da cárie: revisão de literatura.
Brazilian Oral Research,
v. 36,
p. 346-346,
2022.
suppl 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/33574. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BRANDAO, ULISSES
; SPINACE, ESTEVAM V.
; SEKO, MURILO H.; FERREIRA, WILLIAM de P..
Projeto e construção de um sistema de aquecimento por micro-ondas de baixo custo para avaliação de susceptores.
Anais do Workshop de Micro-ondas,
v. 1,
n. 6,
p. 1-4,
2022.
DOI:
10.5281/zenodo.7857092
Abstract:
Este trabalho consistiu no projeto e construção de um forno de micro-ondas de 2,45 GHz, destinado à avaliação de susceptores a serem utilizados como catalisadores, em temperaturas de 400 a 1.100 ºC. Sua construção baseou-se em simulações feitas em computador, seguida de testes e modificações para sua funcionalização.
BRANDAO, ULISSES; SPINACE, ESTEVAM V.; SEKO, MURILO H.; FERREIRA, WILLIAM de P.
Projeto e construção de um sistema de aquecimento por micro-ondas de baixo custo para avaliação de susceptores.
Anais do Workshop de Micro-ondas,
v. 1,
n. 6,
p. 1-4,
2022.
DOI:
10.5281/zenodo.7857092.
Disponível em: http://repositorio.ipen.br/handle/123456789/34095. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PINTO, ANDREIA A.G.; NAGAI, MIRIAN Y. de O.; COIMBRA, EDNAR N.; MOHAMMAD, SUHAM N.
; SILVA, JEFFERSON S.; VON ANCKEN, ADALBERTO; PINTO, SANDRA A.G.; AGUIAR, MICHELLE S.; DUTRA-CORREA, MARISTELA; HORTELLANI, MARCOS A.
; MIRANDA, ADRIANA
; SARKIS, JORGE E. de S.
; SUFFREDINI, IVANA B.; PERES, GIOVANI B.; BERNARDI, MARIA M.; CARTWRIGHT, STEVEN J.; BONAMIN, LEONI V..
Mercury chloride toxicity attenuation of the Brine Shrimp Artemia Salina after treatment with Mercurius corrosivus as isotherapic.
International Journal of High Dilution Research,
v. 21,
n. 2,
p. 6-6,
2022.
DOI:
10.51910/ijhdr.v21i2.1211
Abstract:
Isotherapics prepared from toxic substances have been described as attenuation factors for heavy metal intoxication in aquatic animals. Herein, Artemia salina and mercury chloride were used as a model to identify treatment-related bioresilience. The aim was to describe the effects of Mercurius corrosivus (MC) in different potencies on Artemia salina cyst hatching and on mercury bioavailability. Artemia salina cysts were exposed to 5.0 µg/mL of mercury chloride during the hatching phase. MC 6cH, 30cH, and 200cH were prepared and poured into artificial seawater. Different controls were used (nonchallenged cysts and challenged cysts treated with water, succussed water, and Ethilicum 1cH). Four series of nine experiments were performed for 4 weeks to evaluate the percentage of cyst hatching considering all moon phases. Soluble total mercury (THg) levels and precipitated mercury content were also evaluated. Solvatochromic dyes were used to check for eventual physicochemical markers of MC biological activity. Two-way analysis of variance (ANOVA) with mixed models was used for evaluating the effect of different treatments and the simultaneous influence of the moon phases on the cysts hatching rate, at both observation times (24 and 48 hours). When necessary, outliers were removed, using the Tukey criterion. The level of significance α was set at 5%. Significant delay (p<0.0001) in cyst hatching was observed after treatment with MC 30cH, compared with the controls. An increase in THg concentration in seawater (p<0.0018) and of chlorine/oxygen ratio (p<0.0001) in suspended micro-aggregates was also seen, with possible relation with mercury bioavailability. Specific interaction of MC 30cH with the solvatochromic dye ET33 (p<0.0017) was found. The other observed potencies of Mercurius corrosivus 6 and 200 cH were not significant in relation to the observed groups. The results were postulated as being protective effects of MC 30cH on Artemia salina, by improving its bioresilience.
PINTO, ANDREIA A.G.; NAGAI, MIRIAN Y. de O.; COIMBRA, EDNAR N.; MOHAMMAD, SUHAM N.; SILVA, JEFFERSON S.; VON ANCKEN, ADALBERTO; PINTO, SANDRA A.G.; AGUIAR, MICHELLE S.; DUTRA-CORREA, MARISTELA; HORTELLANI, MARCOS A.; MIRANDA, ADRIANA; SARKIS, JORGE E. de S.; SUFFREDINI, IVANA B.; PERES, GIOVANI B.; BERNARDI, MARIA M.; CARTWRIGHT, STEVEN J.; BONAMIN, LEONI V.
Mercury chloride toxicity attenuation of the Brine Shrimp Artemia Salina after treatment with Mercurius corrosivus as isotherapic.
International Journal of High Dilution Research,
v. 21,
n. 2,
p. 6-6,
2022.
DOI:
10.51910/ijhdr.v21i2.1211.
Disponível em: http://repositorio.ipen.br/handle/123456789/33421. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PANOSSIAN, ZEHBOUR; COSTA, ISOLDA
; ROSSI, JESUALDO L.
.
ICC INTERCORR WCO 2021: A Virtual Edition.
Materials Research,
v. 25,
suppl. 1,
2022.
DOI:
10.1590/1980-5373-MR-2023-E002
Abstract:
Brazil, once again, organized one of the world’s most significant corrosion events, the ICC - INTERNATIONAL CORROSION CONGRESS. In 1978, the 7th edition of the congress was held by ABRACO, in Rio de Janeiro, under the direction of our Dr. Aldo Cordeiro Dutra, chairman of the Executive Committee. To intertwine two events, the 21st ICC was held together with the traditional INTERCORR, the most representative corrosion and corrosion prevention event held in Brazil, organized by ABRACO, in its 8th edition, which included the workshop “Corrosion and Green Energy”, an event of the World Corrosion Organization (WCO). Thus, the ICC INTERCORR WCO 2021 was arranged with this strong partnership.The institutions responsible for organizing the ICC INTERCORR WCO 2021 were: the Brazilian Corrosion Association (ABRACO), the International Corrosion Council (ICC), and the World Corrosion Organization (WCO). To overcome a new post-pandemic Covid-19 reality, the event occurred virtually from July 20th to 23rd, 2021.The ICC INTERCORR WCO 2021 has become a reference for developing the industrial sector, being an excellent forum for presenting new technologies, disseminating knowledge, prospecting for brands, business opportunities and expanding relationships. Its main objective was to encourage the exchange of knowledge between researchers, technicians, professionals, and companies, whether nationally or globally.The ICC INTERCORR WCO 2021 program included the presentation of 6 plenary conferences, 19 lectures, and more than 220 technical articles by renowned specialists from different countries such as Germany, India, Egypt, USA, Portugal, Australia, Italy, Sweden, Spain, Brazil, among others.Today´s moment highlights the importance of promoting such an event in the country, aiming to find solutions to contribute to the recovery that the industrial sector needs. Maintaining the integrity of assets and minimizing operating and maintenance costs are highly relevant concerns in our daily lives, directly impacting the productive sector.Therefore, on behalf of the Executive Committee, we would like to thank all participants and members of the local organizing committee and the scientific committee. We also sincerely thank the support team for collaborating before, during and after this highly successful event.
PANOSSIAN, ZEHBOUR; COSTA, ISOLDA; ROSSI, JESUALDO L.
ICC INTERCORR WCO 2021: A Virtual Edition.
Materials Research,
v. 25,
2022.
suppl. 1,
DOI:
10.1590/1980-5373-MR-2023-E002.
Disponível em: http://repositorio.ipen.br/handle/123456789/34187. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MENDES, V.
; AZEVEDO, L.H.
; ZEZELL, D.M.
.
High-intensity non-ablative lasers in sleep-disordered breathing.
Brazilian Oral Research,
v. 36,
suppl 1,
p. 245-245,
2022.
Abstract:
Primary snoring and severe apnea are considered sleep-disordered breathing and represent different
degrees of severity of the same disorder which affects around one billion people worldwide. It is more
common in men and the elderly. The noise is caused by the soft tissues's vibration in the regions of
greatest constriction of the upper airways. Increased cardiovascular risk, emergence of chronic diseases
and use of medications are due to the progression and evolution of the disease. After determining
optimal irradiation conditions, this study aimed to evaluate the treatment of snoring with sequential
high-intensity non-ablative irradiation with two pulsed lasers Nd:YAG and Er:YAG comparing the
results before and after treatment. A randomized, double-blind, controlled clinical trial is underway
with the approval of the research ethics committee. To date, 32 of 40 volunteers transitioning between
primary snoring and moderate obstructive sleep apnea have been treated in three sessions of nonablative
laser irradiation, 14 days apart. The volume of the oropharyngeal space for air passage was
analyzed by photographic record according to the modified Mallampati index. Oxygen saturation,
snoring severity and sleep quality will also be evaluated. The primary clinical outcome obtained was
the expansion of the upper airway lumen by reducing tissue compliance and, therefore, reducing or
eliminating snoring, in an outpatient procedure.
The reduction of snoring is due to the decrease in tissue compliance.
MENDES, V.; AZEVEDO, L.H.; ZEZELL, D.M.
High-intensity non-ablative lasers in sleep-disordered breathing.
Brazilian Oral Research,
v. 36,
p. 245-245,
2022.
suppl 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/33571. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MONTEIRO, LUCILENA R.
; OLIVEIRA, MERCIA L.; MENEZES, MARIO O.
; POZZO, LORENA
.
Exploratory analysis of a Brazilian real-world open database applied to prostate cancer.
International Journal of Technology Assessment in Health Care,
v. 38,
S1,
p. S97-S98,
2022.
DOI:
10.1017/S0266462322002835
Abstract:
Introduction. Prostate cancer was the second most frequent cancer
and the fifth leading cause of cancer death among men in 2020. The
incidence rates vary substantially in countries with different Human
Development Indexes (HDI), while the mortality rates decrease with
improved access to the health system, availability of therapies and
earlier detection. Worldwide, population-based cancer registries are
important tools for planning and managing health systems. The
Fundação Oncocentro de São Paulo (FOSP) is responsible to collect,
clean and publicize data from cancer treatment institutions. This
study aimed to describe retrospectively the demographic and clinical
profile of prostate cancer (PC) in Brazil using this database. It is not
an incidence study as data is representative only from specific institutions.
Methods. This was a retrospective observational study of the years
2000 to 2020 from analysis of the publicly available FOSP database
(http://www.fosp.saude.sp.gov.br).
The records were extracted, merged, and cleaned using a fully documented
and validated data process. Only patients included on the
register with a primary PC diagnosis were considered.
Results. From January 2010 to June 2020, there were 943,660 patients
diagnosed with C61 in FOSP database for the considered time period.
The majority of the FOSP database records are from patients who live
and/or were born in SP (91.8 and 58.4%, respectively) orMG(2.8 and
10.5%, respectively). The mean age of PC at baseline was 69 years.
Considering the stage of the disease, the mean ages are 55, 70,
67, 66 and 61, for stages 0, 1, 2, 3 and 4, respectively. This cohort
was also analyzed in relation to treatments received, and status at the
end of treatment (51.3% are disease-free, 18.4% are alive with cancer,
and 30.3% are dead). Conclusions. FOSP population-based cancer registries are a powerful
tool to obtain information for planning, and improving the
management of healthcare services especially for São Paulo.
MONTEIRO, LUCILENA R.; OLIVEIRA, MERCIA L.; MENEZES, MARIO O.; POZZO, LORENA.
Exploratory analysis of a Brazilian real-world open database applied to prostate cancer.
International Journal of Technology Assessment in Health Care,
v. 38,
p. S97-S98,
2022.
S1,
DOI:
10.1017/S0266462322002835.
Disponível em: http://repositorio.ipen.br/handle/123456789/33869. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GIMILIANI, GIOVANA T.
; IZAR, GABRIEL.
Difficulties in comparison among different microplastic studies: the inconsistency of results and lack of guide values.
Environmental Toxicology and Chemistry,
v. 41,
n. 4,
p. 820-821,
2022.
DOI:
10.1002/etc.5237
GIMILIANI, GIOVANA T.; IZAR, GABRIEL.
Difficulties in comparison among different microplastic studies: the inconsistency of results and lack of guide values.
Environmental Toxicology and Chemistry,
v. 41,
n. 4,
p. 820-821,
2022.
DOI:
10.1002/etc.5237.
Disponível em: http://repositorio.ipen.br/handle/123456789/33037. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SELLERA, FABIO P.; SABINO, CAETANO P.; NUNEZ, SILVIA C.; RIBEIRO, MARTHA S.
.
Clinical acceptance of antimicrobial photodynamic therapy in the age of WHO global priority pathogens: so what we need to move forward?.
Photodiagnosis and Photodynamic Therapy,
v. 40,
p. 1-3,
2022.
DOI:
10.1016/j.pdpdt.2022.103158
SELLERA, FABIO P.; SABINO, CAETANO P.; NUNEZ, SILVIA C.; RIBEIRO, MARTHA S.
Clinical acceptance of antimicrobial photodynamic therapy in the age of WHO global priority pathogens: so what we need to move forward?.
Photodiagnosis and Photodynamic Therapy,
v. 40,
p. 1-3,
2022.
DOI:
10.1016/j.pdpdt.2022.103158.
Disponível em: http://repositorio.ipen.br/handle/123456789/33456. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CARAMEL-JUVINO, A.
; FONTES-OLIVEIRA, Y.R.
; AVELINO, S.G.
; ZEZELL, D.M.
.
Avaliação da desmineralização superficial do esmalte tratado com flúor e laser utilizando Microscopia Eletrônica de Varredura.
Brazilian Oral Research,
v. 36,
suppl 1,
p. 297-297,
2022.
Abstract:
Avaliar o efeito da aplicação tópica de flúor (12.300 μF-/g) associada a irradiação com laser de Nd:YAG
(84 J/cm2) na desmineralização superficial do esmalte, utilizando imagens de Microscopia Eletrônica
de Varredura (MEV). Utilizou-se 60 amostras de esmalte humano (CAAE: 02854118.3.0000.0075),
divididas em 4 grupos: Controle Negativo, Flúor, Laser e Flúor + Laser (n=15). Após os tratamentos,
os grupos foram subdivididos em 3 (n=5), para ciclagem de pH in vitro simulando três condições
diferentes: pH 5 (abaixo do pH crítico do esmalte), pH 4,5 (abaixo do pH crítico do esmalte na
presença do flúor) e pH 4 (investigativo). Quatro imagens por amostras foram obtidas por MEV a 15
kV, em aumento de 4.000X. As imagens foram classificadas como esmalte hígido, desmineralização
leve, moderada ou severa. Para análise estatística, realizou-se uma normalização, onde a classificação
de desmineralização severa foi equiparada a 100% de desmineralização, 0 foi equiparado à classificação
saudável e as demais classificações foram proporcionais. Em pH 5, os grupos Flúor, Laser e Flúor +
Laser não tiveram diferenças significativas entre si (p>0,05). Em pH 4,5, o grupo Flúor + Laser teve o
menor percentual de desmineralização (p<0,05). Já em pH 4, não houve diferença significativa entre
nenhum grupo.
Os dados sugerem que o tratamento de Flúor + Laser tem ação preventiva mesmo em pH abaixo do
crítico para esmalte na presença do flúor (pH 4,5). Além disso, indica que possivelmente este tratamento
altera o pH crítico da estrutura para valores entre 4,5 e 4, ampliando o poder preventivo do flúor.
CARAMEL-JUVINO, A.; FONTES-OLIVEIRA, Y.R.; AVELINO, S.G.; ZEZELL, D.M.
Avaliação da desmineralização superficial do esmalte tratado com flúor e laser utilizando Microscopia Eletrônica de Varredura.
Brazilian Oral Research,
v. 36,
p. 297-297,
2022.
suppl 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/33572. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SARDO, A.V.N.
; CORRÊA, L.
; PRADO, F.C.R.
; FIGUEIREDO, A.
; ANDRADE, M.F.
; ZEZELL, D.M.
.
Avaliação da área epitelial marcada com CK 10 e CK 14 após fotobiomodulação em mucosite oral induzida por radiação gama.
Brazilian Oral Research,
v. 36,
suppl 1,
p. 143-143,
2022.
Abstract:
A mucosite oral (MO) decorre de tratamento quimoterápico e/ou radioterapico em cabeça e pescoço,
podendo gerar úlceras que predispõem o paciente a quadros infecciosos e álgicos. A fotobiomodulação
(PBM) com laser de baixa intensidade vem sendo destaque nos últimos anos, com bons resultados
clínicos. Poucos trabalhos descrevem a ação da PBM na MO em relação ao amadurecimento
epitelial. As citoqueratinas 10 e 14 (CK10 e CK14) são exemplos de proteínas que podem auxiliar
este raciocínio, sendo a CK 10 característica de queratinócitos com maior grau de diferenciação e a
CK14 de queratinócitos em camadas menos diferenciadas. Este trabalho avaliou a extensão da área
epitelial marcada por meio de imunohistoquímica, positiva para CK10 e CK14, em MO radioinduzida
em língua de ratos e tratada por PBM com laser 660 nm e 789 nm, comparados com grupo não
tratado. As amostras foram coletadas nos dias 8 e 20 após a sessão de irradiação. A área expressando
CK10 foi estatisticamente maior no grupo tratado com laser vermelho no vigésimo dia do experimento
em relação aos demais grupos. Para a CK 14, não houve diferença estatística na quantidade de área
marcada, mas sim na distribuição da marcação desta proteína pelo epitélio, que nos grupos tratados
com PBM encontrava-se restrita a camada basal e no grupo controle encontrava-se também marcada
em camadas mais superiores do epitélio.
Conclui-se que a PBM no tratamento de MO com laser 660 nm aumentou a marcação de CK10 e, para
ambos os comprimentos de onda, restringiu a marcação da CK14 a extratos basais de epitélio, como é
esperado em epitélios normais.
SARDO, A.V.N.; CORRÊA, L.; PRADO, F.C.R.; FIGUEIREDO, A.; ANDRADE, M.F.; ZEZELL, D.M.
Avaliação da área epitelial marcada com CK 10 e CK 14 após fotobiomodulação em mucosite oral induzida por radiação gama.
Brazilian Oral Research,
v. 36,
p. 143-143,
2022.
suppl 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/33570. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta coleção
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
[email protected]
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.