INSTITUTO DE PESQUISAS ENERGÉTICAS E NUCLEARES
Repositório Digital da Produção Técnico Científica

Navegação Eventos - Artigos por Agências de fomento "Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)"

Navegação Eventos - Artigos por Agências de fomento "Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 30192

    FAROOQ, SAJID ; GERMANO, GLEICE ; STANCARI, KLEBER A. ; RAFFAELI, ROCIO; CROCE, MARIA V.; CROCE, ADELA E.; ZEZELL, DENISE M. . A 3D discriminant analysis for hyperspectral FTIR images. In: INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS; SBFOTON INTERNATIONAL OPTICS AND PHOTONICS CONFERENCE, July 31 - August 3, 2023, Campinas, SP. Proceedings... Piscataway, NJ, USA: IEEE, 2023. DOI: 10.1109/OMN/SBFOTONIOPC58971.2023.10230933

    Abstract: Here, we apply a 3D discriminant analysis approach to analyze FTIR hyperspectral images of normal vs malignant Melanoma (MM) samples for skin cancer diagnosis. For this porpose we used 2 samples, for Normal (49k) and for MM(90k). Our results evidence the outstanding performance with accuracy up to 81% for big data (> 100k).

  • IPEN-DOC 26077

    ANA, PATRICIA A.; PEREIRA, DAISA de L. ; FERREIRA, ELIZABETE dos S.; FIGUEREDO, DANIELA C.; DAGUANO, JULIANA K.F.B.; ZEZELL, DENISE M. . Advances in the prevention and monitoring of root dentin demineralization using lasers. In: SBFOTON INTERNATIONAL OPTICS AND PHOTONICS CONFERENCE, October 7-9, 2019, São Paulo, SP. Proceedings... 2019.

    Abstract: The increase in the life expectancy and the longer permanence of the teeth in the oral cavity also led to an augment in the prevalence of root caries lesions. These lesions require more attention because of their rapid progression and difficulty in early diagnosis and monitoring. In this context, the irradiation of the tissues with high intensity lasers has been shown as an important way for preventing lesion formation because lasers chemically modify the irradiated dental hard tissues and make them more resistant to acid challenge. In addition, the association with ceramic biomaterials may allow additional remineralizing results. Together with therapeutics, the effective early diagnosis of incipient lesions is indispensable. Techniques that use lasers, such as optical coherence tomography, have also been promising in this aspect because they allow the early diagnosis and monitoring of demineralizations with high resolution and in a non-detrimental way. This article aims to show the actions of high intensity laser therapies when associated or not with biomaterials, on the prevention and remineralization of root caries lesions, as well as the effectiveness of optical coherence tomography in the diagnosis and monitoring the effects of the treatments in these lesions.

  • IPEN-DOC 30043

    BAFFA, MATHEUS de F.O.; BACHMANN, LUCIANO; ZEZELL, DENISE M. ; PEREIRA, THIAGO M.; DESERNO, THOMAS M.; FELIPE, JOAQUIM C.. Advancing thyroid pathologies detection with recurrent neural networks and micro-FTIR hyperspectral imaging. In: ALMEIDA, JOAO R. (Ed.); SPILIOPOULOU, MYRA (Ed.); ANDRADES, JOSE A.B. (Ed.); PLACIDI, GIUSEPPE (Ed.); GONZALEZ, ALEJANDRO R. (Ed.); SICILIA, ROSA (Ed.); KANE, BRIDGET (Ed.) INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, 36th, June 22-24, 2023, L’Aquila, Italy. Proceedings... Piscataway, NJ, USA: IEEE, 2023. p. 611-615. DOI: 10.1109/CBMS58004.2023.00288

    Abstract: Thyroid disorders are a complex group of diseases that require an accurate diagnosis for effective treatment. Fine-needle aspiration biopsies can assist in detecting many thyroid diseases. These materials can be analyzed visually using traditional computer vision methods, despite the limitations of complex samples. To address this problem, we propose a novel approach that uses hyperspectral imaging (HSI) to analyze thyroid biological samples. HSI measures the absorbance of infrared light by biological samples using a micro Fourier transform infrared spectroscopy (micro-FTIR) and converts this data into hyperspectral images. In this study, we used HSI to train and validate a recurrent neural network to classify thyroid samples as healthy, cancerous, or goiter. Our experiments, based on the k-fold cross-validation, achieved an overall accuracy of 96.88%, a sensitivity of 96.87%, and a specificity of 98.45%. These results demonstrate the potential of hyperspectral imaging as a tool to assist pathologists in the diagnosis of thyroid disease.

  • IPEN-DOC 26762

    SIERRA, JULIAN H.; CARVALHO, DANIEL O.; SAMAD, RICARDO E. ; RANGEL, RICARDO C.; ALAYO, MARCO I.. Analysis and measurement of the non-linear refractive index of SiOxNy using pedestal waveguides. In: SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES, 34th, August 26-30, 2019, São Paulo, SP. Proceedings... Piscataway, NJ, USA: IEEE, 2019. DOI: 10.1109/SBMicro.2019.8919392

    Abstract: In this work, the non-linear refractive index (n2) of silicon oxynitride (SiOxNy) is determined, obtaining a value for this material of n2 = 2.11×10-19 m2/W. The results demonstrate that this material has interesting properties for the development of non-linear optical devices. The paper presents in detail the waveguide fabrication process using the pedestal technique, which allows using different materials since it does not require etching to define the sidewalls of the waveguides. We show the results of the measurement of the n2 employing the non-linear optical phenomena of Self-Phase Modulation (SPM).

    Palavras-Chave: optical equipment; photons; silicon nitrides; silicon oxides; microelectronics

  • IPEN-DOC 26133

    ABREU, RODRIGO T. ; ANGELOCCI, LUCAS V. ; NOGUEIRA, BEATRIZ R. ; SANTOS, HAMONA N. dos ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Anisotropy function of a new 192-Ir brachytherapy source. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 175-185.

    Abstract: Brachytherapy is a type of radiotherapy that uses radioactive sources (seeds, wires, among others) close to the tumor. Is important to provide a detailed description of seed dosimetry, so only the tumor will be irradiated avoiding unnecessary dose on adjacent organs and structures. To evaluate the dosimetric parameter of the anisotropy function for a new brachytherapy source, this work proposes the use of microcube TLD-100 dosimeters to find the dose rate using the AAPM Task Group 43 protocol (TG-43). The anisotropy function represents dose distribution around the source and has a major role for characterization of a new iridium source being implemented in Brazil. The value of D(r,θ) was measured using Solid Water phantoms, r value being the distance from the geometric center of the source to the position of the dosimeter on the phantom, and θ being the angle formed between the longitudinal axis of the source and the line connecting the geometric center to the TLD. Monte Carlo calculations were performed to evaluate the anisotropy function to validate the experimental measurements. For each distance value (r), an anisotropy function was plotted (1.0, 2.0, 3.0, 4.0, 5.0, and 10.0 cm). The results obtained with Monte Carlo calculations agreed ±2% with the experimental values for r greater than 3.0 cm, so these results show a good distribution of dose around the seed considering the high energy of 192-Ir (average of 380 KeV) and encapsulation thickness.

    Palavras-Chave: anisotropy; brachytherapy; dose rates; dosimetry; iridium 192; monte carlo method; phantoms; radiation dose distributions; radiation source implants; sealed sources; thermoluminescent dosemeters

  • IPEN-DOC 24876

    OLIANI, WASHINGTON L. ; PARRA, DUCLERC F. ; KOMATSU, LUIZ G.H. ; LINCOPAN, NILTON; RANGARI, VIJAYA K.; LUGAO, ADEMAR B. . Antibacterial effect of silver incorporated polyethylene blown film for active packaging use. In: CONGRESSO BRASILEIRO DE POLIMEROS, 14., 22-26 de outubro, 2017, Águas de Lindóia, SP. Anais... 2017. p. 2433-2437.

    Abstract: Food packaging is used to maintain the quality and safety of food products during storage and transportation, and to extend the shelf-life of food products. This is done by preventing unfavourable factors or conditions such as oxygen, light, moisture, spoilage microorganisms, chemical contaminants, mechanical resistance, etc. To be able to do so, packaging materials provide physical protection and also create the proper physicochemical conditions for each product necessary to obtain adequate shelf life and maintain food quality and safety. We report the preparation of polyethylene blown films containing silver nanoparticles by using the ultrasound technique. The silver nitrate was mixed with the surfactant oleic acid (AO) and sonicated for 30 minutes. This solution was mixed with polyethylene using a rotary mixer for 12 hours. Nanocomposites of low density polyethylene (LDPE) with linear low density polyethylene (LLDPE) blends and silver nanoparticles were prepared under melt in a twin screw extruder, using PE-g-MA as compatibilizer agent, ethylene graft maleic anhydride copolymer. The films were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDX), field emission scanning electron microscopy (FESEM), differential scanning calorimetry (DSC), percentage reduction of colony-forming units (CFU). The bacterial effect of Escherichia coli and Staphylococcus aureus were assessed in detail.

  • IPEN-DOC 21675

    TERADA, MAYSA ; RAMASCO, BRUNO T.; SIMOES, ALDA M.P.; PADILHA, ANGELO F.; COSTA, ISOLDA . Aplicação da microscopia eletroquímica de varredura no estudo da corrosão do aço inoxidável DIN W. Nr. 1.4460 com alto teor de nitrogênio. In: CONGRESSO BRASILEIRO DE CORROSAO, 28.; INTERNATION CORROSION MEETING, 2nd, May 12-16, 2008, Recife, PE. Anais... 2008. p. 1-21.

    Abstract: Neste trabalho, a microscopia eletroquímica de varredura (SECM) foi usada para investigar a concentração de espécies químicas liberadas pela corrosão e avaliar a resistência à corrosão localizada do aço inoxidável austenítico DIN W. Nr. 1.4460 com alto N. Este material apresenta potencialidade para aplicação como biomaterial pela completa ausência de fases ferromagnéticas. O potencial do ultra microeletrodo detectou não somente íons Fe2+ nas áreas anódicas, mas também o empobrecimento em oxigênio nas regiões catódicas. O aço foi ensaiado nas condições como recebido e solubilizado. Os resultados indicaram que o material como recebido apresenta superfície mais ativa que a do solubilizado. Análise da superfície por “Field Emission Gun” (FEG-SEM) mostrou grande quantidade de Cr2N os quais atuaram como nucleadores de pites, e que a corrosão se inicia na interface precipitado de nitreto/matriz.

    Palavras-Chave: corrosion; stainless steels; austenitic steels; corrosion resistance; nitrogen; surgical materials

  • IPEN-DOC 27944

    KOMATSU, LUIZ G.H. ; OLIANI, WASHINGTON L. ; LUGAO, ADEMAR B. ; PARRA, DUCLERC F. . Aplicação de ZnO como carregador de prata em uma blenda de HMSPP/SEBS visando ação biocida / Aplication of ZnO as carrier of silver in the blend of HMSPP/SEBS for biocide activity. In: CONGRESSO BRASILEIRO DE POLÍMEROS, 15., 27-31 de outubro, 2019, Bento Gonçalves-RS. Anais... São Carlos, SP: Associação Brasileira de Polímeros, 2019. p. 2356-2359.

    Abstract: Este estudo consiste em utilizar o óxido de zinco (ZnO) como carregador de nanoprata metálica (Ag°). Foi testado um método para síntese das partículas com a prata, o método de Turkevich. A confecção dos filmes poliméricos em matriz de HMSPP/SEBS foi realizada via processamento no estado fundido em extrusora. Os materiais obtidos foram caracterizados pelas técnicas de DLS, MEV e ensaios biocidas. As partículas apresentaram-se em tamanhos variando entre 100 à 200 nm, juntamente a isso, elas também apresentaram resultados de morte celular nos ensaios biocidas com as bactérias E.coli e S.aureus de acordo com a norma JIZ 2801.

    Palavras-Chave: films; polymers; zinc oxides; nanoparticles; silver; disinfectants; bacteria

  • IPEN-DOC 26141

    COTIS, DÉBORA S.; MARQUES, LEILA S.; FIGUEIREDO, ANA M.G. ; CORVAL, ARTUR; VALENTE, SÉRGIO C.. Application of neutron activation analysis to the study of low-titanium tholeiitic dykes of the Serra do Mar Swarm (RJ). In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 330-343.

    Abstract: The tholeiitic dykes of the Serra do Mar Swarm (SMS) outcrop along the coast of the São Paulo and Rio de Janeiro states (Southeastern Brazil), spreading over the Rio Paraiba Valley. Previous studies carried out in such dykes showed that they are related to the tectonic and magmatic processes that took place during the South Atlantic Ocean opening and gave rise to the Paraná Magmatic Province (PMP). The dykes are vertical to subvertical and preferentially NE-SW trending, with thicknesses ranging from centimeters to tens of meters. Most of the SMS intrusive rocks have relatively high concentrations of TiO2 (>3wt%), except for occurrences in the Região dos Lagos (Costa Azul Suite), as well as around Nova Friburgo Town (Serrana Suite), where they are characterized by basic rocks with low TiO2 (<2wt%) contents, whose genesis are still not completely understood. Therefore, a detailed study is being carried out in rocks of the Suite Serrana, with the determination of the concentrations of the rare earth (REE: La, Ce, Nd, Sm, Eu, Tb, Yb, and Lu) and other trace (Ta, Th, U, Hf, Cs, Sc, and Co) elements by instrumental neutron (thermal and epithermal) activation analysis, which has accuracy and precision required for petrogenetic studies. The data obtained so far show a substantial enrichment of highly incompatible trace elements (light REE, Th and U) and a remarkable geochemical similarity with the low-TiO2 basaltic flows of Gramado type found in southern PMP, suggesting important processes of crustal contamination during the genesis of the investigated dykes.

    Palavras-Chave: elements; geology; igneous rocks; neutron activation analysis; radioisotopes; titanium; trace amounts; brazil

  • IPEN-DOC 26766

    LIMA, CASSIO A. ; CORREA, LUCIANA; BYRNE, HUGH J.; ZEZELL, DENISE M. . Assessing the spectrochemical signatures of skin components using FTIR microspectroscopy. In: QUINCY BROWN, J. (Ed.); VAN LEEUWEN, TON G. (Ed.) EUROPEAN CONFERENCES ON BIOMEDICAL OPTICS, June 23-27, 2019, Munich, Germany. Proceedings... Bellingham, WA, USA: SPIE, 2019. p. 110730S-1 - 110730S-3. (Proceedings of SPIE-OSA Vol. 11073, Clinical and Preclinical Optical Diagnostics II). DOI: 10.1117/12.2527137

    Abstract: Fourier Transform Infrared (FTIR) spectroscopy is a label-free analytical technique used to evaluate the chemical profile of a sample based on its molecular vibrations. The potential dermatological applications of FTIR spectroscopy has been well demonstrated over the past decades through many proof-of-concept studies evaluating cancerous and non-cancerous cutaneous diseases. Considering that the correctly identification of skin components plays an important role in the study of cutaneous diseases, the present study aims to evaluate the spectrochemical signatures of dermis and epidermis based on the pixels of a FTIR hyperspectral image collected from healthy skin.

    Palavras-Chave: infrared spectrometers; skin; epithelium; cluster analysis

  • IPEN-DOC 25607

    CASTRO, PEDRO ; ZORN, TELMA; ZEZELL, DENISE . Biochemical characterization of skin burn wound healing using ATR-FTIR. In: SBFOTON INTERNATIONAL OPTICS AND PHOTONICS CONFERENCE, October 08-10, 2018, Campinas, SP. Proceedings... Piscataway, NJ, USA: IEEE, 2018. DOI: 10.1109/SBFoton-IOPC.2018.8610943

    Abstract: Efficient biochemical characterization of skin burn healing stages can improve clinical routine to adjust patients treatment. The golden standard for diagnosing skin burning stages is the histological biopsy. This practice is often expensive and technically challenging. There have been advances in the treatment, and diagnostic of the critical skin burned patients due to the increase of multidisciplinary collaboration. The contributions from different fields of biomedical engineering motivate to develop a better procedure for clinical applications. Considering the difficulty of monitoring wound healing the Fourier Transform Infrared coupled with an Attenuated Total Reflectance (ATR-FTIR) accessory is an analytical technique that can provide information regarding spectral biomarkers in biological materials. This study aimed to evaluate the classification feasibility provided by ATR-FTIR technique in the burned skin to follow the regenerative process in vivo. 40 skin burned samples from the Wistar rats dorsum at 3,7, 14, 21 days after burn were compared with the corresponded healthy group samples, by registering their infrared absorption spectra in FTIR Thermo Nicolet 6700 coupled to a diamond crystal ATR. The spectra were separated in the region 900 to 1800 cm-1 for further chemometric calculations. The second derivative of spectra was applied for discrimination, which results demonstrated differences from control and burns wounded groups, as well as among, burn wounded groups, using Amide I (1628 cm-1) and Amide II (1514 cm-1) bands. Amide I and Amide II bands are two significant bands of the infrared protein spectrum. The Amide I band is mainly associated with the C=O stretching vibration (70-80%) and is directly related to the backbone conformation. The Amide II band results from the N-H bending vibration (40-60%) and from the C-N stretching vibration (18-40%). This band is conformationally sensitive. These bands suggest proteins activity changing associate to inflammatory and maturation stages when it is compared with the healthy group. The statistical difference with amide I occur in proliferation and maturation stages. These findings indicate that ATR-FTIR is suitable to detect the burn wound healing stages and in the future can be an auxiliary instrument for clinical routine.

  • IPEN-DOC 29344

    CASTRO, PEDRO A.A. de ; DIAS, DERLY A. ; VELOSO, MARCELO N. ; ZEZELL, DENISE M. . Bone as a biomarker for detecting low dose of ionizing radiation: a pilot study. In: LATIN AMERICA OPTICS AND PHOTONICS CONFERENCE, August 7-11, 2022, Recife, PE. Proceedings... Washington, DC, USA: Optica Publishing Group, 2022. DOI: 10.1364/LAOP.2022.M2B.4

    Abstract: FTIR spectroscopy was able to discriminate bone samples receiving low-dose ionizing radiation doses (0.002 kGy, 0.004 kGy, 0.007 kGy), offering valuable insights in view of the understanding of radiation dose response in biological systems.

  • IPEN-DOC 29346

    DEL-VALLE, MATHEUS ; SANTOS, MOISES O. dos ; BERNARDES, EMERSON S. ; ZEZELL, DENISE M. . Breast cancer subtype classification using a one-dimensional convolutional neural network in hyperspectral images. In: LATIN AMERICA OPTICS AND PHOTONICS CONFERENCE, August 7-11, 2022, Recife, PE. Proceedings... Washington, DC, USA: Optica Publishing Group, 2022. DOI: 10.1364/LAOP.2022.M4B.5

    Abstract: FTIR spectroscopy imaging in addition to deep learning is a potential tool for breast cancer subtype classification, where accuracies higher than 86% can be achieved to predict among all subtypes.

  • IPEN-DOC 26784

    LITVAC, DANIEL ; CALDAS, LINDA V.E. . Calibration of a clinical beta therapy applicator using the thermoluminescence samples: preliminary results. In: CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3., 24-27 de novembro, 2019, Florianópolis, SC. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2019.

    Abstract: In some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, even with the higher efficiency of linear accelerators because they are of lower cost and easier use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate is essential to ensure accuracy in clinical treatments. In this work the thermoluminescent response of BeO and μLiF pellets was evaluated, determining the reproducibility, linearity of response and their dose-response curves. This standard, for this type of calibration, recommends the use of small detectors such as μLiF. Therefore, the utility of μLiF and BeO in the calibration of clinical applicators was compared.

    Palavras-Chave: beryllium oxides; lithium fluorides; beta particles; calibration; comparative evaluations; dosimetry; radiation sources; therapy; thermoluminescence

  • IPEN-DOC 25545

    LITVAC, DANIEL ; CALDAS, LINDA V.E. . Caracterização dosimétrica do BeO para calibração de aplicadores clínicos de betaterapia. In: CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIACOES IONIZANTES, 26-28 de novembro, 2018, Rio de Janeiro, RJ. Anais... 2018. p. 1-8.

    Abstract: Aplicadores clínicos de 90Sr + 90Y ainda são utilizados em algumas partes do Brasil para tratamentos dermatológicos e oftálmicos, mesmo com a recomendação do uso de aceleradores lineares, porque são de custo mais baixo e práticos. A calibração e a recalibração periódica destes aplicadores, para verificação da taxa de dose absorvida, são essenciais para garantir a segurança nos tratamentos clínicos. Neste trabalho foi avaliada a resposta termoluminescente de pastilhas de BeO e se são aplicáveis a um planejamento de calibração de aplicadores clínicos de betaterapia, porque o material dosimétrico que era utilizado neste planejamento não é mais produzido no IPEN.

    Palavras-Chave: beryllium oxides; beta dosimetry; brazilian cnen; calibration; recommendations; thermoluminescence; yttrium 90

  • IPEN-DOC 26758

    ROVANI, S. ; CARVALHO, F. ; SANTOS, J.; RAMOS, N.; MORANDI, M.; SALDANHA, M.; FUNGARO, D. . Caracterização físico-química das propriedades de cinzas de cana-de-açúcar de diferentes usinas brasileiras. In: CONGRESSO BRASILEIRO DE QUÍMICA, 59., 5-8 de novembro, 2019, João Pessoa, PB. Anais... Rio de Janeiro, RJ: Associação Brasileira de Química, 2019.

    Abstract: O interesse em transformar biomassa em novas fontes de energia e novos materiais vem fomentando estudos em todo o mundo. As cinzas resultantes da queima de palha e bagaço de cana, por exemplo, é um material rico em sílica. No presente estudo, amostras de cinzas de resíduos de cana-de-açúcar foram coletadas nas usinas de Cerradinho (Chapadão do Céu, GO), Iracema (Iracemápolis, SP) e Guaíra (Guaíra, SP), localizadas em regiões onde os solos são classificados como Latossolos. As cinzas foram caracterizadas pelas técnicas de XRD, EDX, MEV, espectroscopia no IV e DTG. A maioria das amostras de cinzas apresentou sílica como principal constituinte (42-69%) e a sílica na forma cristalina em todas. Diferenças significativas nas concentrações de outros elementos foram observadas.

    Palavras-Chave: sugar cane; ashes; silica; biomass

  • IPEN-DOC 27026

    PEREIRA, T.M. ; DIEM, M.; BIRD, B.; MILJKOVIC, M.; ANA, P.A.; BACHMANN, L.; ZEZELL, D.M. . Caracterização por espectroscopia no infravermelho de colóides tireoidianos sadios e hiperplásicos. In: CONGRESSO BRASILEIRO DE ENGENHARIA BIOMÉDICA, 24., 13-17 de outubro, 2014, Uberlândia, MG. Anais... Bauru, SP: Canal 6, 2014. p. 1115-1118.

    Abstract: O presente trabalho mostra a caracterização da Tiroglobulina contidos nos colóides tireoidianos por espectroscopia no infravermelho. A produção da tiroglobulina é alterada em pacientes com Bócio Nodular. Assim, as informações bioquímicas desta glicoiodoproteina podem ser utilizada como indicador desta disfunção. Os resultados utilizando espectroscopia no infravermelho revela diferenças bioquímicas nas conformação da proteína, hormônios e carboidratos.

    Palavras-Chave: endocrine glands; thyroid; proteins; infrared spectrometers; diagnosis

  • IPEN-DOC 26744

    VILLANI, D. ; SAVI, M. ; ANDRADE, M.A.B.; CAMPOS, L.L. ; POTIENS, M.P.A. . Characterization of ABS + W and ABS + Bi 3D printing filaments attenuation for different photon beams. In: CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3., 24-27 de novembro, 2019, Florianópolis, SC. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2019.

    Abstract: 3D printing techniques and materials have become widely available in the last couple of decades and remains a hot topic of study as new materials can lead to new applications. This study aims to evaluate the attenuation behaviour of GMASS over photon beams ranging from 29.7 up to 661.7keV, comparing with pure ABS and using theoretical data of pure lead as reference. It was used the transmission method to obtain experimental attenuation coefficients to all materials and theoretical data. HVL and TVL calculations were also performed. Results show that ABS+W has higher attenuation than ABS+Bi and pure ABS. Using the lead theoretical reference data it can be concluded that although ABS+Bi and ABS+W attenuates less than pure lead, the 3D printing filaments can be used to create shielding tolls depending on radiation energy and application.

    Palavras-Chave: attenuation; cesium 137; dosimetry; energy dependence; filaments; photon beams; polymers; radiations; shielding

  • IPEN-DOC 24103

    CASTRO, PEDRO A.A. de ; DIAS, DERLY A. ; ZEZELL, DENISE M. . Characterization of ionizing radiation effects on bone using Fourier Transform Infrared Spectroscopy and multivariate analysis of spectra. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: Ionizing radiation has been used as an important treatment and diagnostic method for several diseases. Optical techniques provides an efficient clinical diagnostic to support an accurate evaluation of the interaction of radiation with molecules. Fourier-transform infrared spectroscopy coupled with attenuated total reflectance (ATR-FTIR) is a label-free and nondestructive optical technique that can recognize functional groups in biological samples. In this work, 30 fragments of bone were collected from bovine femur diaphysis. Samples were cut and polished until 1 cm x 1 cm x 1 mm, which were then stored properly in the refrigerated environment. Samples irradiation was performed with a Cobalt-60 Gammacell Irradiator source at doses of 0.1 kGy, 1 kGy, whereas the fragments exposed to dose of 15 kGy was irradiated in a multipurpose irradiator of Cobalt-60. Spectral data was submitted to principal component analysis followed by linear discriminant analysis. Multivariate analysis was performed with Principal component analysis(PCA) followed by Linear Discriminant Analysis(LDA) using MATLAB R2015a software (The Mathworks Inc., Natick, MA, USA). We demonstrated the feasibility of using ATR-FTIR spectroscopy associated with PCA-LDA multivariate technique to evaluate the molecular changes in bone matrix caused by different doses: 0.1 kGy, 1 kGy and 15 kGy. These alterations between the groups are mainly reported in phosphate region. Our results open up new possibilities for protein monitoring relating to dose responses.

    Palavras-Chave: cattle; cobalt 60; femur; fourier transformation; infrared spectra; ionizing radiations; multivariate analysis; radiation dose ranges; radiation doses; radiation effects

  • IPEN-DOC 25532

    MILAGRE, MARIANA X. ; ARAUJO, JOAO V. de S. ; GOMES, MAURILIO P. ; DONATUS, UYIME ; MACHADO, CARULINE S.C. ; COSTA, ISOLDA . Comparison of the corrosion resistance of AA2024 and AA2098 alloys in different solutions. In: EUROPEAN CORROSION CONGRESS: APPLIED SCIENCE WITH CONSTANT AWARENESS, September 9-13, 2018, Krakow, Poland. Proceedings... Krakow: European Federation of Corrosion, 2018.

    Abstract: In this work the corrosion resistance of the AA2098-T351 and AA2024-T3 was evaluated and compared by electrochemical tests in 0.01 mol.L-1 of NaCl and 0.1 mol.L-1 of Na2SO4 with 0.001 mol.L-1 NaCl electrolytes. Monitoring of corrosion evolution in both alloys was carried out by electrochemical impedance spectroscopy (EIS) and polarization methods. The surface of the samples exposed to the test solutions was observed by microscopy after corrosion tests. The results showed different corrosion mechanisms in the two test solutions. In the sulfate containing electrolyte, the Al-Cu-Li alloy showed corrosion mechanism mainly associated with the micrometric particles at the surface, similarly to the AA2024-T3 alloy. However, in the chloride solution without sulfate, the AA2098-T351 alloy showed susceptibility to severe localized corrosion (SLC) besides the corrosion associated to the micrometric particles and the first type of corrosion was the main type of attack. The AA2024-T3 showed lower susceptibility to SLC than the AA2098- T351 alloy.

    Palavras-Chave: corrosion resistance; corrosion resistant alloys; monitoring; electrochemistry; polarization; aluminium alloys; lithium alloys; spectroscopy; copper alloys

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, [email protected] .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.